西門子6ES7151-7AA21-0AB0 6ES7151-7AA21-0AB0價(jià)格
西門子ET-200S 6ES7151-7AA21-0AB0
SIMATIC ET 200S, CPU, IM151-8 PN/DP CPU
---------------------------
上海君俞自動(dòng)化科技有限公司
聯(lián)系 人 : 袁昊
24小時(shí)服務(wù)熱線:138 1874 7209
傳真(Fax):+86-021-37653206
工作 (Q Q) : 835304981
郵箱(Email):8353041981@qq.com
----------------------------
|
注:
CPU 運(yùn)行需要 SIMATIC 微存儲(chǔ)卡(MMC)
IM 151-8 PN/DP CPU 可用于運(yùn)行中等大小程序的遠(yuǎn)程、分布式自動(dòng)化解決方案。 可現(xiàn)場(chǎng)對(duì)處理數(shù)據(jù)進(jìn)行遠(yuǎn)程預(yù)處理,并能傳送上位控制單元所需的數(shù)據(jù)。 這樣做有以下幾個(gè)優(yōu)點(diǎn):
IM 151-8 PN/DP CPU 運(yùn)行并不完全依賴于中央控制器。 如果故障,IM 151-8 PN/DP CPU 可輕松繼續(xù)運(yùn)行。
位模塊化設(shè)計(jì)的 ET 200S I/O 系統(tǒng)和 IM 151-8 PN/DP CPU 為面向功能的站設(shè)計(jì)。
IM 151-8 PN/DP CPU 配有以下部件:
帶有 IM 151-8 PN/DP CPU 的 ET 200S 可以在 STEP7 系統(tǒng)內(nèi)在網(wǎng)絡(luò)上的任何點(diǎn)上編程、組態(tài)和診斷。
151-8AB008AB01
|
6ES7 151-8AB01-0AB0 |
General information |
|
Hardware product version |
01 |
Firmware version |
V3.2 |
Engineering with |
|
|
STEP7 V 5.5 or higher |
Supply voltage |
|
24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Reverse polarity protection |
Yes; against destruction |
External protection for supply cables (recommendation) |
2 A min. |
Mains buffering |
|
|
5 ms |
Input current |
|
Inrush current, max. |
1.8 A; Typical |
I2t |
0.13 A2·s |
from supply voltage 1L+, max. |
352 mA; 426 mA with DP master module |
Output current |
|
Current output to backplane bus (DC 5 V), max. |
700 mA |
Power losses |
|
Power loss, typ. |
5.5 W |
Memory |
|
Work memory |
|
|
192 kbyte |
|
No |
|
64 kbyte |
Load memory |
|
|
Yes |
|
8 Mbyte |
|
10 a |
Backup |
|
|
Yes; Ensured by SIMATIC Micro Memory Card (maintenance-free) |
CPU processing times |
|
for bit operations, typ. |
0.06 μs |
for word operations, typ. |
0.12 μs |
for fixed point arithmetic, typ. |
0.16 μs |
for floating point arithmetic, typ. |
0.59 μs |
CPU-blocks |
|
Number of blocks (total) |
1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB |
|
|
1 024; Number range: 1 to 16000 |
|
64 kbyte |
FB |
|
|
1 024; Number range: 0 to 7999 |
|
64 kbyte |
FC |
|
|
1 024; Number range: 0 to 7999 |
|
64 kbyte |
OB |
|
|
See S7-300 operation list |
|
64 kbyte |
|
1; OB 1 |
|
1; OB 10 |
|
2; OB 20, 21 |
|
4; OB 32, 33, 34, 35 |
|
1; OB 40 |
|
3; OB 55, 56, 57 |
|
1; OB 61; only for PROFINET |
|
1; OB 100 |
|
6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO) |
|
2; OB 121, 122 |
Nesting depth |
|
|
16 |
|
4 |
Counters, timers and their retentivity |
|
S7 counter |
|
|
256 |
|
|
|
Yes |
|
0 |
|
255 |
|
Z 0 to Z 7 |
|
|
|
Yes |
|
0 |
|
999 |
IEC counter |
|
|
Yes |
|
SFB |
|
Unlimited (limited only by RAM capacity) |
S7 times |
|
|
256 |
|
|
|
Yes |
|
0 |
|
255 |
|
No retentivity |
|
|
|
10 ms |
|
9 990 s |
IEC timer |
|
|
Yes |
|
SFB |
|
Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
|
Flag |
|
|
256 byte |
|
Yes |
|
MB 0 to MB 15 |
|
8; 1 memory byte |
Data blocks |
|
|
1 024; Number range: 1 to 16000 |
|
64 kbyte |
|
Yes; via non-retain property on DB |
|
Yes |
Local data |
|
|
32 768 byte; Max. 2048 bytes per block |
Address area |
|
I/O address area |
|
|
2 048 byte |
|
2 048 byte |
|
|
|
2 048 byte |
|
2 048 byte |
Process image |
|
|
2 048 byte |
|
2 048 byte |
|
128 byte |
|
128 byte |
Subprocess images |
|
|
1; With PROFINET IO, the length of the user data is limited to 1600 bytes |
Digital channels |
|
|
16 336 |
|
16 336 |
|
496 |
|
496 |
Analog channels |
|
|
1 021 |
|
1 021 |
|
124 |
|
124 |
Hardware configuration |
|
Number of modules per system, max. |
63; Centralized |
Mounting rail |
|
|
1 |
|
Station width: <= 1 m or < 2 m |
Time of day |
|
Clock |
|
|
Yes |
|
Yes |
|
10 s; Typ.: 2 s |
|
6 wk; At 40 °C ambient temperature, typically |
|
Clock continues running after POWER OFF |
|
Clock continues to run with the time at which the power failure occurred |
Operating hours counter |
|
|
1 |
|
0 |
|
0 to 2^31 hours (when using SFC 101) |
|
1 hour |
|
Yes; Must be restarted at each restart |
Clock synchronization |
|
|
Yes |
|
No |
|
No |
|
Yes; With DP master module |
|
Yes; With DP master module |
|
No |
|
No |
|
Yes; As client |
Interfaces |
|
Interfaces |
1x PROFINET (3 RJ45 ports) |
Number of USB interfaces |
0 |
Number of parallel interfaces |
0 |
Number of other interfaces |
1; Ethernet, 3-port switch, 3*RJ45 |
PROFINET IO |
|
|
3; 3 ports (incl. switch) |
WLAN |
|
|
0 |
1st interface |
|
Interface type |
PROFINET |
Physics |
Ethernet |
Isolated |
Yes |
Integrated switch |
Yes |
Number of ports |
3; RJ45 |
Automatic detection of transmission speed |
Yes |
Autonegotiation |
Yes |
Autocrossing |
Yes |
Change of IP address at runtime, supported |
Yes |
Media redundancy |
|
|
Yes |
|
200 ms; PROFINET MRP |
|
50 |
Functionality |
|
|
No |
|
No |
|
No |
|
Yes; Also simultaneously with IO Controller functionality |
|
Yes; Also simultaneously with IO-Device functionality |
|
Yes |
|
Yes |
|
Yes |
|
5 |
|
No |
PROFINET IO Controller |
|
|
100 Mbit/s; full duplex |
|
128 |
|
128 |
|
128 |
|
128 |
|
61 |
|
64 |
|
64 |
|
Yes |
|
Yes |
|
Yes |
|
32 |
|
Yes |
|
8 |
|
Yes |
|
8 |
|
Yes |
|
250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) |
|
Minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items. |
|
250 μs to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU") |
|
|
|
Yes |
|
Yes; With DP master module |
|
Yes; with loadable FBs |
|
Yes; OB 61; only for PROFINET IO |
|
Yes; Via TCP/IP, ISO on TCP, and UDP |
|
|
|
2 kbyte |
|
2 kbyte |
|
1 024 byte; with PROFINET I/O |
PROFINET IO Device |
|
|
|
|
Yes |
|
Yes |
|
Yes; with loadable FBs |
|
No |
|
Yes; Via TCP/IP, ISO on TCP, and UDP |
|
Yes |
|
Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device |
|
Yes |
|
2 |
|
|
|
1 440 byte; Per IO Controller with shared device |
|
1 440 byte; Per IO Controller with shared device |
|
|
|
64 |
|
1 024 byte |
PROFINET CBA |
|
|
Yes |
|
Yes |
Open IE communication |
|
|
Yes; Via TCP/IP, ISO on TCP, and UDP |
|
8 |
|
0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
2nd interface |
|
Interface type |
External interface via master module 6ES7138-4HA00-0AB0 |
Physics |
RS 485 |
Isolated |
Yes |
Power supply to interface (15 to 30 V DC), max. |
No |
Functionality |
|
|
No |
|
Yes |
|
No |
|
No |
|
No |
|
No |
|
No |
|
No |
DP master |
|
|
12 Mbit/s |
|
32; Per station |
|
|
|
Yes |
|
Yes |
|
No |
|
Yes; I blocks only |
|
Yes |
|
No |
|
Yes |
|
Yes |
|
No |
|
Yes |
|
Yes |
|
8 |
|
Yes |
|
Yes |
|
|
|
2 048 byte |
|
2 048 byte |
|
|
|
244 byte |
|
244 byte |
Isochronous mode |
|
Isochronous operation (application synchronized up to terminal) |
No |
Communication functions |
|
PG/OP communication |
Yes |
Data record routing |
Yes; With DP master module |
Global data communication |
|
|
No |
S7 basic communication |
|
|
Yes; I blocks |
|
76 byte |
|
76 byte |
S7 communication |
|
|
Yes |
|
Yes |
|
Yes; via integrated PROFINET interface and loadable FBs |
|
See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
Open IE communication |
|
|
Yes; via integrated PROFINET interface and loadable FBs |
|
8 |
|
1 460 byte |
|
32 768 byte |
|
Yes |
|
Yes; via integrated PROFINET interface and loadable FBs |
|
8 |
|
32 768 byte |
|
Yes; via integrated PROFINET interface and loadable FBs |
|
8 |
|
1 472 byte |
Web server |
|
|
Yes |
|
5 |
|
Yes |
PROFINET CBA (at set setpoint communication load) |
|
|
50 % |
|
32 |
|
30 |
|
1 000 |
|
4 000 byte |
|
4 000 byte |
|
500 |
|
4 000 byte |
|
1 400 byte |
|
|
|
500 ms |
|
100 |
|
100 |
|
2 000 byte |
|
2 000 byte |
|
1 400 byte |
|
|
|
1 ms |
|
200 |
|
200 |
|
2 000 byte |
|
2 000 byte |
|
450 byte |
|
|
|
3; 2x PN OPC/1x iMap |
|
500 ms |
|
200 |
|
2 000 byte |
|
|
|
Yes |
|
16 |
|
240 byte; Slave-dependent |
iPAR server |
|
|
Yes |
Number of connections |
|
|
12 |
|
11 |
|
1 |
|
1 |
|
11 |
|
11 |
|
1 |
|
1 |
|
11 |
|
10 |
|
0 |
|
0 |
|
10 |
|
10; with loadable FBs |
|
10 |
|
32 |
|
4; With DP master module |
S7 message functions |
|
Number of login stations for message functions, max. |
12; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages |
Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ |
simultaneously active Alarm-S blocks, max. |
300 |
Test commissioning functions |
|
Status block |
Yes; Up to 2 simultaneously |
Single step |
Yes |
Number of breakpoints |
4 |
Status/control |
|
|
Yes |
|
Inputs, outputs, memory bits, DB, times, counters |
|
30 |
|
30 |
|
14 |
Forcing |
|
|
Yes |
|
I/O |
|
10 |
Diagnostic buffer |
|
|
Yes |
|
500 |
|
No |
|
100; Only the last 100 entries are retained |
Interrupts/diagnostics/status information |
|
Alarms |
|
|
Yes |
Diagnostic messages |
|
|
Yes |
Diagnostics indication LED |
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
Galvanic isolation |
|
between PROFIBUS DP and all other circuit components |
Yes |
Permissible potential difference |
|
between different circuits |
75 VDC / 60 VAC |
Isolation |
|
Isolation checked with |
500 V DC |
Degree and class of protection |
|
IP (rear) |
IP20 |
Configuration |
|
Configuration software |
|
|
Yes; V5.5 or higher |
programming |
|
|
see instruction list |
|
8 |
|
see instruction list |
|
see instruction list |
|
|
|
Yes |
|
Yes |
|
Yes |
|
Yes; Optional |
|
Yes; Optional |
|
Yes; Optional |
|
Yes; Optional |
Know-how protection |
|
|
Yes |
|
Yes; With S7 block Privacy |
Cycle time monitoring |
|
|
1 ms |
|
6 000 ms |
|
Yes |
|
150 ms |
Dimensions |
|
Width |
120 mm; DP master module: 35 mm |
Height |
119.5 mm |
Depth |
75 mm |
Weights |
|
Weight, approx. |
320 g; DP master module: Approx. 100 g |