細分數(shù)
|
1
|
2
|
4
|
5
|
8
|
10
|
20
|
25
|
40
|
50
|
100
|
200
|
200
|
200
|
200
|
200
|
D0
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
D1
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
D2
|
ON
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
D3
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
D4
|
ON,
雙脈沖:PU為正向步進脈沖信號,DR為反向步進脈沖信號
|
|||||||||||||||
OFF,
單脈沖:PU為步進脈沖信號,DR為方向控制信號
|
細分數(shù)
|
1
|
2
|
4
|
8
|
16
|
32
|
64
|
128
|
D0
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
ON
|
OFF
|
D1
|
ON
|
ON
|
OFF
|
OFF
|
ON
|
ON
|
OFF
|
OFF
|
D2
|
ON
|
ON
|
ON
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
D3
|
無效
|
|||||||
D4
|
ON,
雙脈沖:PU為正向步進脈沖信號,DR反向步進脈沖信號
|
|||||||
OFF,
單脈沖:PU為步進脈沖信號,DR為方向控制信號
|
標(biāo)記符號
|
功能
|
注釋
|
O.H
|
故障指示燈
|
過熱保護時紅色發(fā)光管點亮
|
TM
|
工作指示燈
|
TM信號有效時,綠色指示燈點亮
|
Im
|
電機線圈電流設(shè)定電位器
|
調(diào)整電機相電流,逆時針減小,順時針增大
|
+
|
輸入信號光電隔離正端
|
接+5V供電電源,+5V-+24V均可驅(qū)動,高于+5V需接限流電阻
|
PU
|
D4=OFF,PU為步進脈沖信號
|
下降沿有效,每當(dāng)脈沖由高變低時電機走一步。輸入電阻220Ω,要求:低電平0-0.5V,高電平4-5V,脈沖寬度>2.5μS
|
D4=ON,PU為正向步進脈沖信號
|
||
+
|
輸入信號光電隔離正端
|
接+5V供電電源,+5V-+24V均可驅(qū)動,高于+5V需接限流電阻
|
DR
|
D4=OFF,DR為方向控制信號
|
用于改變電機轉(zhuǎn)向。輸入電阻220Ω,要求:低電平0-0.5V,高電平4-5V,脈沖寬度>2.5μS
|
D4=ON,DR為反向步進脈沖信號
|
||
+
|
輸入信號光電隔離正端
|
接+5V供電電源,+5V-+24V均可驅(qū)動,高于+5V需接限流電阻
|
MF
|
電機釋放信號
|
有效(低電平)時關(guān)斷電機線圈電流,驅(qū)動器停止工作,電機處于自由狀態(tài)
|
+
|
原點輸出光電隔離正端
|
電機線圈通電位于原點置為有效(B、-A通電);光電隔離輸出(高電平)
|
TM
|
原點輸出信號光電隔離負端
|
+端接輸出信號限流電阻,TM接輸出地。最大驅(qū)動電流50mA,最高電壓50V
|
+V
|
電源正極
|
DC12-40V
|
-V
|
電源負極
|
|
AC、BC
|
電機接線
|
|
+A、-A
|
||
+B、-B
|