a.電位器的電阻值為1K2、5K2。
The resistance valve of the potentionmeter is 1kn, 5KO
b.用手柄轉(zhuǎn)動動閥門到全閉位置。
Rotate the valve and reach to close the b compleby with the handle
C.松開電位器,轉(zhuǎn)動動電位器齒輪,用萬能表測量4-5接線端子間的電阻值,使4-5的電阻值到
52以下,緊固電位器固定螺釘。(如果是智能型的七線接插件連接時請測量對RV和RS兩插插孔的電阻值)
Unclamp the potentionmeter rotate the gear wheel of the potentionmeter measure the resistance valve among4-5wiring sons of end with the universal meter nable the resistance valve of 4-under 50, fasten the potentionmeter fixed screw.(if please measuer the resistance value to RV and RS two jake when being that inbligent Line seven connects the plug-in package connection
注:手動操作時,不能過分超出全開,全關(guān)的極限位置,轉(zhuǎn)角過大,會導致其部件的損壞
Note: At the time of manual operation, can t go beyond and is open excessively compleb he terminal b that is closed compleby. the comer is too big, will cause its part s damage
3.機械限位的調(diào)整
Adjustment of the mechanism spacing
a.用手柄轉(zhuǎn)動到全開位置
Rotate to compleby opening b with the handle
b.松開鎖緊螺母,旋轉(zhuǎn)調(diào)整螺釘,使只與機械擋擋塊接觸,然后反方向旋轉(zhuǎn)螺釘半圈,鎖緊螺毋。
Unclamp the locknut, rotate and adjust the screwenable it and machinery block one and keep in touch, then, rotate semi circke of screw, the locknut in the opposite direction
c.同樣的方法,可進行全閉位置的機械擋塊的調(diào)整。
The same b, can close the adjustment of blocking one of machinery of the b compleby.